Model: UT-2088
● Standard RS-232 input interface (RS-485, TCP/IP interface optional)
● Standard DB25 output interface
● 16-channel opto-isolated relay output
● 8-channel opto-isolated voltage input and 8-channel opto-isolated switch input
● Power input: AC100-240V/50~60Hz
● Switching output using terminal blocks
● Power consumption: 12W Max.
● Maximum contact capacity (DC): 110VDC 0.3A 30VDC 1A
● Maximum contact capacity (AC): 125VAC 0.3A
● With communication indicator indication
● Operating environment: -25~ 70°C, relative humidity 5~95%
UT-2088 data parallel input/output (I/O) control card is 8-bit 16-channel data input, 8-bit 16-channel data output, all data input and output are compatible with TTL/DTL level, each data input or output channel is similar to a number of personal computer interface, using external RS-232 and RS-485 opto-isolated communication interface, this type of computer I/O box is very easy to use the program to control the functions of those input/output ports, plus simple drive lines to drive external devices (e.g.: pneumatic components, external relay switches, electric eye states, remote control interface instruments, analog-to-digital-to-analog converters, EEPROM electrically erasable memory read/write, stepper motor control, etc.).
● Standard RS-232 input interface (RS-485, TCP/IP interface optional)
● Standard DB25 output interface
● 16-channel opto-isolated relay output
● 8-channel opto-isolated voltage input and 8-channel opto-isolated switch input
● Power input: AC100-240V/50~60Hz
● Switching output using terminal blocks
● Power consumption: 12W Max.
● Maximum contact capacity (DC): 110VDC 0.3A 30VDC 1A
● Maximum contact capacity (AC): 125VAC 0.3A
● With communication indicator indication
● Operating environment: -25~ 70°C, relative humidity 5~95%
Interface Definition
Pin Assignment |
RS-232 |
RS-485 |
1 |
N/C |
RS-485- |
2 |
RXD |
RS-485+ |
3 |
TXD |
N/C |
4 |
N/C |
N/C |
5 |
GND |
GND |
6 |
N/C |
N/C |
7 |
N/C |
N/C |
8 |
N/C |
N/C |
9 |
N/C |
N/C |